1. 草莓视频APP色版,草莓视频污污下载,草莓小黄片,草莓成人在线视频

      Professional Switch Manufacturer
      Service Hotline:13712077807

      Tap switch circuit load

      Release Time:2020-03-18

       
       
      Touch the switch circuit load details. I hope it can be convenient for you to use.
       
      The type of tap switch circuit load
       
      1. Resistance load
       
      Resistance load refers to the power factor (COS φ = 1) under resistance load only. The rating mark of the switch indicates the current capacity when AC is used.
       
      2. DC load
       
      In the case of DC load, different from AC, because the current direction is constant, the arc duration is longer under the same voltage.
       
      3. Incandescent lamp load
       
      When the lamp is on, after the switch is set to on, because the impact current flowing in the instant is 10-15 times of the normal current, contact adhesion may occur. Please consider the transition current when selecting the switch.
       
      4. Inductive load
       
      In the case of inductive load (relay, solenoid, buzzer, etc.), the arc caused by reverse potential will be generated, which may cause contact failure. Therefore, it is recommended to insert appropriate spark elimination circuit (refer to the figure below).
       
      5. Motor load
       
      When the motor starts, the starting current flowing through is 3-8 times of the normal current, so the contact adhesion may occur. Depending on the type of motor, but the current flowing is several times of the nominal current, so please refer to the values shown in the table below when selecting the switch. In addition, when the motor rotates reversely, it is necessary to consider that when the on-off-on switch is used, the multiplication current (starting current + reverse starting current) should be avoided.
       
      In the case of reverse rotation, the current flowing is about 2 times of the starting current. In addition, due to the influence of time delay, arc short-circuit (circuit short-circuit) may occur between poles during switching when it is used for load with transition phenomenon, such as reverse rotation operation of motor, or different pole switching, etc. Please pay attention when using.
       
      6. Capacitive load
       
      In case of capacitive load of mercury lamp, fluorescent lamp and capacitor circuit, when the switch is on, it will flow through a very large impact current. Therefore, please use the actual load to measure its transition value and confirm whether it is used within the range of rated current. Use the actual load to confirm before use. S

      Online

      Online
      Contact Us

      Hotline

      0769-85330959

      mobiles

      13712077807

      Wechat
      ONLINE
      網站地圖草莓APP色版下载安装 草莓成人APP在线观看 草莓APP在线观看 午夜免费视频 91桃色在线观看 蜜桃视频在线观看污 黄瓜视频黄片下载 91小黄片下载